Abstract: In multiple sclerosis (MS) the gold standard for the diagnosis and prognosis is, up to now, the use of magnetic resonance imaging markers. No alternative simpler assays proven of use, except for cerebrospinal fluid analysis, have been provided in MS diagnosis. Therefore, there is a need to develop non-invasive, sensitive, simple new techniques for the clinical routine. Herein we present the evaluation of the feasibility of a glycopeptide-based biosensor to detect MS specific antibodies in sera using the surface plasmon resonance technology. The previously described glycopeptide antigen CSF114(Glc) has been immobilized on a gold sensor chip and the method has been optimized for real-time specific autoantibody detection directly in sera. A population of 60 healthy blood donors and 61 multiple sclerosis patients has been screened. The receiver operating characteristic (ROC)-based analysis has established the optimal diagnostic cut-off value for the method obtaining a sensitivity of 36% and a specificity of 95%. Sample sera have been also screened with a previously validated ELISA.

Glycopeptide-Based Antibody Detection in Multiple Sclerosis by Surface Plasmon Resonance / F. Real-Fernandez; I. Passalacqua; E. Peroni; M.Chelli; F.Lolli; A.M. Papini; P. Rovero. - In: SENSORS. - ISSN 1424-8220. - STAMPA. - 12:(2012), pp. 5596-5607. [10.3390/s120505596]

Glycopeptide-Based Antibody Detection in Multiple Sclerosis by Surface Plasmon Resonance

REAL FERNANDEZ, FELICIANA;LOLLI, FRANCESCO;PAPINI, ANNA MARIA;ROVERO, PAOLO
2012

Abstract

Abstract: In multiple sclerosis (MS) the gold standard for the diagnosis and prognosis is, up to now, the use of magnetic resonance imaging markers. No alternative simpler assays proven of use, except for cerebrospinal fluid analysis, have been provided in MS diagnosis. Therefore, there is a need to develop non-invasive, sensitive, simple new techniques for the clinical routine. Herein we present the evaluation of the feasibility of a glycopeptide-based biosensor to detect MS specific antibodies in sera using the surface plasmon resonance technology. The previously described glycopeptide antigen CSF114(Glc) has been immobilized on a gold sensor chip and the method has been optimized for real-time specific autoantibody detection directly in sera. A population of 60 healthy blood donors and 61 multiple sclerosis patients has been screened. The receiver operating characteristic (ROC)-based analysis has established the optimal diagnostic cut-off value for the method obtaining a sensitivity of 36% and a specificity of 95%. Sample sera have been also screened with a previously validated ELISA.
2012
12
5596
5607
F. Real-Fernandez; I. Passalacqua; E. Peroni; M.Chelli; F.Lolli; A.M. Papini; P. Rovero
File in questo prodotto:
File Dimensione Formato  
sensors-12-05596.pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 334.36 kB
Formato Adobe PDF
334.36 kB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/649641
Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 30
social impact