The discovery of the so-called Lazarus effect, namely the recovery of the charge collection efficiency (CCE) of irradiated silicon detectors by means of cryogenic cooling has entailed an increasing interest in the behavior of silicon detectors at cryogenic temperatures. We have measured the CCE of a silicon p-i-n diode detector previously irradiated with an equivalent fluence of 1 x 10(15) n/cm(2) neutrons of 1 MeV energy. The charge collection efficiency has been measured at 77 ii;. showing that the low-temperature operation considerably decreases the bias current. This is also the case when forward voltage bias is applied, which then becomes a suitable option. In this condition, the sample shows a charge collection efficiency in excess of 65% at 250 V corresponding to a most probable signal for a minimum ionizing particle of 21000e(-)

Radiation hard position-sensitive cryogenic silicon detectors: the Lazarus effect / V.G Palmieri;M.C Abreu;W.H Bell;P Berglund;W de Boer;E Borchi;K Borer;M Bruzzi;S Buontempo;L Casagrande;S Chapuy;V Cindro;N D'Ambrosio;C.Da Viá;S Devine;B Dezillie;Z Dimcovski;V Eremin;A Esposito;V Granata;E Grigoriev;F Hauler;E Heijne;S Heising;S Janos;L Jungermann;I Konorov;Z Li;C Lourenço;M Mikuẑ;T.O Niinikoski;V O'Shea;S Pagano;S Paul;S Pirollo;K Pretzl;P Rato;G Ruggiero;K Smith;P Sonderegger;P Sousa;E Verbitskaya;S Watts;M Zavrtanik. - In: PHYSICA. B, CONDENSED MATTER. - ISSN 0921-4526. - STAMPA. - 280:(2000), pp. 532-534. [10.1016/S0921-4526(99)01853-0]

Radiation hard position-sensitive cryogenic silicon detectors: the Lazarus effect

BORCHI, EMILIO;BRUZZI, MARA;
2000

Abstract

The discovery of the so-called Lazarus effect, namely the recovery of the charge collection efficiency (CCE) of irradiated silicon detectors by means of cryogenic cooling has entailed an increasing interest in the behavior of silicon detectors at cryogenic temperatures. We have measured the CCE of a silicon p-i-n diode detector previously irradiated with an equivalent fluence of 1 x 10(15) n/cm(2) neutrons of 1 MeV energy. The charge collection efficiency has been measured at 77 ii;. showing that the low-temperature operation considerably decreases the bias current. This is also the case when forward voltage bias is applied, which then becomes a suitable option. In this condition, the sample shows a charge collection efficiency in excess of 65% at 250 V corresponding to a most probable signal for a minimum ionizing particle of 21000e(-)
2000
280
532
534
V.G Palmieri;M.C Abreu;W.H Bell;P Berglund;W de Boer;E Borchi;K Borer;M Bruzzi;S Buontempo;L Casagrande;S Chapuy;V Cindro;N D'Ambrosio;C....espandi
File in questo prodotto:
File Dimensione Formato  
physicaB2802000532.pdf

Accesso chiuso

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Tutti i diritti riservati
Dimensione 91.65 kB
Formato Adobe PDF
91.65 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/676812
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 2
social impact