CVD diamond material was used to build position-sensitive detectors for single-charged particles to be employed in high-intensity physics experiments. To obtain position information, metal contacts shaped as strips or pixels are applied to the detector surface for one- or two-dimensional coordinate measurement. Strip detectors 2 x 4 cm(2) in size with a strip distance of 50 mum were tested. Pixel detectors of various pixel sizes were bump bonded to electronics chips and investigated. A key issue for the use of these sensors in high intensity experiments is the radiation hardness. Several irradiation experiments were carried out with pions, protons and neutrons exceeding a fluence of 10(15) particles/cm(2). The paper presents an overview of the results obtained with strip and pixel detectors in high-energy test beams and summarises the irradiation studies.

CVD diamond sensors for charged particle detection / M. Krammer, W. Adam, E. Berdermann, P. Bergonzo, G. Bertuccio, F. Bogani, E. Borchi, A. Brambilla, M. Bruzzi, C. Colledani, J. Conway, P. D'Angelo, W. Dabrowski, P. Delpierre, A. Deneuville, W. Dulinski, B. van Eijk, A. Fallou, F. Fizzotti, F. Foulon, et al.. - In: DIAMOND AND RELATED MATERIALS. - ISSN 0925-9635. - STAMPA. - 10:(2001), pp. 1778-1782. [10.1016/S0925-9635(01)00446-0]

CVD diamond sensors for charged particle detection

BOGANI, FRANCO;BORCHI, EMILIO;BRUZZI, MARA;SCIORTINO, SILVIO;
2001

Abstract

CVD diamond material was used to build position-sensitive detectors for single-charged particles to be employed in high-intensity physics experiments. To obtain position information, metal contacts shaped as strips or pixels are applied to the detector surface for one- or two-dimensional coordinate measurement. Strip detectors 2 x 4 cm(2) in size with a strip distance of 50 mum were tested. Pixel detectors of various pixel sizes were bump bonded to electronics chips and investigated. A key issue for the use of these sensors in high intensity experiments is the radiation hardness. Several irradiation experiments were carried out with pions, protons and neutrons exceeding a fluence of 10(15) particles/cm(2). The paper presents an overview of the results obtained with strip and pixel detectors in high-energy test beams and summarises the irradiation studies.
2001
10
1778
1782
M. Krammer;W. Adam;E. Berdermann;P. Bergonzo;G. Bertuccio;F. Bogani;E. Borchi;A. Brambilla;M. Bruzzi;C. Colledani;J. Conway;P. D'Angelo;W....espandi
File in questo prodotto:
File Dimensione Formato  
DRM1020011778.pdf

Accesso chiuso

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Tutti i diritti riservati
Dimensione 399.04 kB
Formato Adobe PDF
399.04 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/676823
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 12
social impact