CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article, we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a beta-source and the performance before and after intense (> 10(15)/cm(2)) proton- and pion-irradiations. We find that low dose irradiation increase the signal-to-noise ra io (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiation with protons 2.2 x 10(15) p/cm(2) lowers the signal-to-noise ratio slightly. Intense irradiation with pions 2.9 x 10(15) pi/cm(2) lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations.

Performance of irradiated CVD diamond micro-strip sensors / W Adam;E Berdermann;P Bergonzo;G Bertuccio;F Bogani;E Borchi;A Brambilla;M Bruzzi;C Colledani;J Conway;P D'Angelo;W Dabrowski;P Delpierre;A Deneuville;W Dulinski;B van Eijk;A Fallou;F Fizzotti;F Foulon;M Friedl;K.K Gan;E Gheeraert;G Hallewell;S Han;F Hartjes;J Hrubec;D Husson;H Kagan;D Kania;J Kaplon;R Kass;T Koeth;M Krammer;A Logiudice;R Lu;L mac Lynne;C Manfredotti;D Meier;M Mishina;L Moroni;J Noomen;A Oh;L.S Pan;M Pernicka;A Peitz;L Perera;S Pirollo;M Procario;J.L Riester;S Roe;L Rousseau;A Rudge;J Russ;S Sala;M Sampietro;S Schnetzer;S Sciortino;H Stelzer;R Stone;B Suter;R.J Tapper;R Tesarek;W Trischuk;D Tromson;E Vittone;A.M Walsh;R Wedenig;P Weilhammer;M Wetstein;C White;W Zeuner;M Zoeller;R Plano;S.V Somalwar;G.B Thomson. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 476:(2002), pp. 706-712. [10.1016/S0168-9002(01)01671-0]

Performance of irradiated CVD diamond micro-strip sensors

BOGANI, FRANCO;BORCHI, EMILIO;BRUZZI, MARA;SCIORTINO, SILVIO;
2002

Abstract

CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article, we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a beta-source and the performance before and after intense (> 10(15)/cm(2)) proton- and pion-irradiations. We find that low dose irradiation increase the signal-to-noise ra io (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiation with protons 2.2 x 10(15) p/cm(2) lowers the signal-to-noise ratio slightly. Intense irradiation with pions 2.9 x 10(15) pi/cm(2) lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations.
2002
476
706
712
W Adam;E Berdermann;P Bergonzo;G Bertuccio;F Bogani;E Borchi;A Brambilla;M Bruzzi;C Colledani;J Conway;P D'Angelo;W Dabrowski;P Delpierre...espandi
File in questo prodotto:
File Dimensione Formato  
nima4762002706.pdf

Accesso chiuso

Tipologia: Altro
Licenza: Tutti i diritti riservati
Dimensione 230.84 kB
Formato Adobe PDF
230.84 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/676828
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 13
social impact