Abstract Following a widespread trend in international research on R744 cooling applications, the authors have developed a test rig for investigating refrigerating cycles and equipment which operates with such refrigerant. The facility was designed aiming to a compact layout and to a high flexibility in terms of cycles and pieces of equipment to be tested. The test rig can operate stand-alone thanks to a passive load management system which works with water as secondary fluid. The paper gives some useful data, based on direct experience, for the realization and management of a multi-purpose test rig that allows the analysis of several cycle layouts over wide operating ranges. Some of the main critical issues related to proper plant and component design, a correct choice of the measurement equipment and a suitable system management are shown and discussed. The paper also includes experimental data obtained while testing a reciprocating compressor and a single-stage cycle layout both with and without using an internal heat exchanger.
Setup and characterisation of a multi-purpose test rig for R744 refrigerating cycles and equipment / Andrea Chesi;Giovanni Ferrara;Lorenzo Ferrari;Fabio Tarani. - In: INTERNATIONAL JOURNAL OF REFRIGERATION. - ISSN 0140-7007. - ELETTRONICO. - 35:(2012), pp. 1848-1859. [10.1016/j.ijrefrig.2012.06.005]
Setup and characterisation of a multi-purpose test rig for R744 refrigerating cycles and equipment
CHESI, ANDREA;FERRARA, GIOVANNI;FERRARI, LORENZO;TARANI, FABIO
2012
Abstract
Abstract Following a widespread trend in international research on R744 cooling applications, the authors have developed a test rig for investigating refrigerating cycles and equipment which operates with such refrigerant. The facility was designed aiming to a compact layout and to a high flexibility in terms of cycles and pieces of equipment to be tested. The test rig can operate stand-alone thanks to a passive load management system which works with water as secondary fluid. The paper gives some useful data, based on direct experience, for the realization and management of a multi-purpose test rig that allows the analysis of several cycle layouts over wide operating ranges. Some of the main critical issues related to proper plant and component design, a correct choice of the measurement equipment and a suitable system management are shown and discussed. The paper also includes experimental data obtained while testing a reciprocating compressor and a single-stage cycle layout both with and without using an internal heat exchanger.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S014070071200151X-main.pdf
Accesso chiuso
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Tutti i diritti riservati
Dimensione
1.03 MB
Formato
Adobe PDF
|
1.03 MB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.