Abstract—Nonlinear ultrasound methods are widely used in clinical applications for tissue or contrast harmonic imaging. Accurate non-linear imaging simulation tools are required in research studies for the development of new methods. However, in existing simulators, the possible inhomogeneity of the coefficient of non-linearity, which is generally observed in tissue and in particular when contrast agents are involved, has not yet been implemented. This article describes a new ultrasound simulator, called CREANUIS, devoted to the computation of B-mode images where both linear and non-linear propagation in media is considered, with a possible inhomogeneous coefficient of non-linearity. The resulting fundamental images, based on a spatially variant and non-linear point spread function, are in accordance with those obtained through the reference linear FieldII simulator, with computation time reduced by a factor of at least 1.8. Non-linear images of media exhibiting inhomogeneous coefficients of non-linearity are also provided. The simulation software can be freely downloaded from our website.
CREANUIS: A Nonlinear Radio Frequency Ultrasound Image Simulator / F.Varray; O. Basset; P. Tortoli; C. Cachard. - In: ULTRASOUND IN MEDICINE AND BIOLOGY. - ISSN 0301-5629. - STAMPA. - 10:(2013), pp. 2818-2824. [10.1016/j.ultrasmedbio.2013.04.005]
CREANUIS: A Nonlinear Radio Frequency Ultrasound Image Simulator
VARRAY, FRANCOIS;TORTOLI, PIERO;
2013
Abstract
Abstract—Nonlinear ultrasound methods are widely used in clinical applications for tissue or contrast harmonic imaging. Accurate non-linear imaging simulation tools are required in research studies for the development of new methods. However, in existing simulators, the possible inhomogeneity of the coefficient of non-linearity, which is generally observed in tissue and in particular when contrast agents are involved, has not yet been implemented. This article describes a new ultrasound simulator, called CREANUIS, devoted to the computation of B-mode images where both linear and non-linear propagation in media is considered, with a possible inhomogeneous coefficient of non-linearity. The resulting fundamental images, based on a spatially variant and non-linear point spread function, are in accordance with those obtained through the reference linear FieldII simulator, with computation time reduced by a factor of at least 1.8. Non-linear images of media exhibiting inhomogeneous coefficients of non-linearity are also provided. The simulation software can be freely downloaded from our website.File | Dimensione | Formato | |
---|---|---|---|
UMB13_CREANUIS.pdf
Accesso chiuso
Descrizione: Articolo
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Tutti i diritti riservati
Dimensione
1.86 MB
Formato
Adobe PDF
|
1.86 MB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.