Comparing the performance of different contrast imaging techniques can be difficult and somewhat confusing, since the tests were typically made using different in vitro setups, contrast agents, ultrasound transducers and systems. In this study, we report on the implementation of arbitrary contrast-pulse-sequences (CPS) in the ULA-OP open ultrasound system. Combined with a home-made phantom, a convenient and consistent evaluation of the main parameters characterizing various techniques is obtained. Several experiments were performed exciting BR14 microbubbles at a dilution between 1/200 and 1/800, with an average MI = 0.1, through 10 different excitation schemes including power modulation, chirp reversal and their combination. Chirp Amplitude Modulation (CAM) and Chirp Reversal Amplitude Modulation (CRAM) showed the best performance with an average CTR of 34 dB.

Implementation of arbitrary contrast imaging strategies on an US Open Platform / Francesco Guidi; Riccardo Mori; Jacopo Viti; Nico de Jong; Piero Tortoli. - ELETTRONICO. - (2012), pp. 683-686. (Intervento presentato al convegno 2012 IEEE International Ultrasonics Symposium (IUS) tenutosi a Dresden nel 7-10 October 2012) [10.1109/ULTSYM.2012.0170].

Implementation of arbitrary contrast imaging strategies on an US Open Platform

GUIDI, FRANCESCO;MORI, RICCARDO;VITI, JACOPO;TORTOLI, PIERO
2012

Abstract

Comparing the performance of different contrast imaging techniques can be difficult and somewhat confusing, since the tests were typically made using different in vitro setups, contrast agents, ultrasound transducers and systems. In this study, we report on the implementation of arbitrary contrast-pulse-sequences (CPS) in the ULA-OP open ultrasound system. Combined with a home-made phantom, a convenient and consistent evaluation of the main parameters characterizing various techniques is obtained. Several experiments were performed exciting BR14 microbubbles at a dilution between 1/200 and 1/800, with an average MI = 0.1, through 10 different excitation schemes including power modulation, chirp reversal and their combination. Chirp Amplitude Modulation (CAM) and Chirp Reversal Amplitude Modulation (CRAM) showed the best performance with an average CTR of 34 dB.
2012
2012 IEEE International Ultrasonics Symposium
2012 IEEE International Ultrasonics Symposium (IUS)
Dresden
7-10 October 2012
Francesco Guidi; Riccardo Mori; Jacopo Viti; Nico de Jong; Piero Tortoli
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/827516
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact