In this paper, we propose a method to improve the lateral resolution and the contrast of ultrasound images, based on the cancellation of the sole contribution due to the sidelobes, thus maintaining the original depth of field and penetration capability. In the proposed method, each scan line is obtained by compounding the signals reconstructed by two emissions. For the first one, typical aperture and apodization profile are adopted. In the second emission, the same aperture is used, but the sign of the apodization profile is inverted over the second half of the aperture. The same approach is applied in receive. In this way, the second two-way beam has a main lobe with near-zero amplitude and sidelobes close to those of the first beam. The RF echo-signals corresponding to the two emissions are demodulated and successively subtracted. The resulting signal is finally log-compressed and scan converted. Simulations and in vivo experiments show a significant improvement of both detail and contrast resolution.

Improved lateral resolution and contrast in ultrasound imaging using a sidelobe masking technique / A. Stuart Savoia; G. Caliano; G. Matrone; G. Magenes; A. Ramalli; E. Boni; P. Tortoli. - ELETTRONICO. - (2014), pp. 1682-1685. (Intervento presentato al convegno 2014 IEEE International Ultrasonics Symposium tenutosi a Chicago nel September 2014) [10.1109/ULTSYM.2014.0417].

Improved lateral resolution and contrast in ultrasound imaging using a sidelobe masking technique

RAMALLI, ALESSANDRO;BONI, ENRICO;TORTOLI, PIERO
2014

Abstract

In this paper, we propose a method to improve the lateral resolution and the contrast of ultrasound images, based on the cancellation of the sole contribution due to the sidelobes, thus maintaining the original depth of field and penetration capability. In the proposed method, each scan line is obtained by compounding the signals reconstructed by two emissions. For the first one, typical aperture and apodization profile are adopted. In the second emission, the same aperture is used, but the sign of the apodization profile is inverted over the second half of the aperture. The same approach is applied in receive. In this way, the second two-way beam has a main lobe with near-zero amplitude and sidelobes close to those of the first beam. The RF echo-signals corresponding to the two emissions are demodulated and successively subtracted. The resulting signal is finally log-compressed and scan converted. Simulations and in vivo experiments show a significant improvement of both detail and contrast resolution.
2014
2014 IEEE International Ultrasonics Symposium Proceedings
2014 IEEE International Ultrasonics Symposium
Chicago
September 2014
A. Stuart Savoia; G. Caliano; G. Matrone; G. Magenes; A. Ramalli; E. Boni; P. Tortoli
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/914943
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 6
social impact