Although severely affected by the angle dependency, carotid artery peak systolic velocity measurements are widely used for assessment of stenosis. In this study, blood peak systolic velocities in the common and internal carotid arteries of both healthy volunteers and patients with internal carotid artery stenosis were measured by two vector Doppler (VD) methods and compared with measurements obtained with the conventional spectral Doppler approach. Although the two VD techniques were completely different (using the transmission of focused beams and plane waves, respectively), the measurement results indicate that these techniques are nearly equivalent. The peak systolic velocities measured in 22 healthy common carotid arteries by the two VD techniques were very close (according to Bland-Altman analysis, the average difference was 3.2%, with limits of agreement of ±8.6%). Application of Bland-Altman analysis to comparison of either VD technique with the spectral Doppler method provided a 21%-25% average difference with ±13%-15% limits of agreement. Analysis of the results obtained from 15 internal carotid arteries led to similar conclusions, indicating significant overestimation of peak systolic velocity with the spectral Doppler method. Inter- and intra-operator repeatability measurements performed in a group of 8 healthy volunteers provided equivalent results for all of the methods (coefficients of variability in the range 2.7%-6.9%), even though the sonographers were not familiar with the VD methods. The results of this study suggest that the introduction of vector Doppler methods in commercial machines may finally be considered mature and capable of overcoming the angle-dependent overestimation typical of the standard spectral Doppler approach.

Comparison of Carotid Artery Blood Velocity Measurements by Vector and Standard Doppler Approaches / Tortoli, Piero; Lenge, Matteo; Righi, Daniele; Ciuti, Gabriele; Liebgott, Herve; Ricci, Stefano. - In: ULTRASOUND IN MEDICINE AND BIOLOGY. - ISSN 0301-5629. - STAMPA. - 41:(2015), pp. 1354-1362. [10.1016/j.ultrasmedbio.2015.01.008]

Comparison of Carotid Artery Blood Velocity Measurements by Vector and Standard Doppler Approaches

TORTOLI, PIERO;LENGE, MATTEO;RICCI, STEFANO
2015

Abstract

Although severely affected by the angle dependency, carotid artery peak systolic velocity measurements are widely used for assessment of stenosis. In this study, blood peak systolic velocities in the common and internal carotid arteries of both healthy volunteers and patients with internal carotid artery stenosis were measured by two vector Doppler (VD) methods and compared with measurements obtained with the conventional spectral Doppler approach. Although the two VD techniques were completely different (using the transmission of focused beams and plane waves, respectively), the measurement results indicate that these techniques are nearly equivalent. The peak systolic velocities measured in 22 healthy common carotid arteries by the two VD techniques were very close (according to Bland-Altman analysis, the average difference was 3.2%, with limits of agreement of ±8.6%). Application of Bland-Altman analysis to comparison of either VD technique with the spectral Doppler method provided a 21%-25% average difference with ±13%-15% limits of agreement. Analysis of the results obtained from 15 internal carotid arteries led to similar conclusions, indicating significant overestimation of peak systolic velocity with the spectral Doppler method. Inter- and intra-operator repeatability measurements performed in a group of 8 healthy volunteers provided equivalent results for all of the methods (coefficients of variability in the range 2.7%-6.9%), even though the sonographers were not familiar with the VD methods. The results of this study suggest that the introduction of vector Doppler methods in commercial machines may finally be considered mature and capable of overcoming the angle-dependent overestimation typical of the standard spectral Doppler approach.
2015
41
1354
1362
Tortoli, Piero; Lenge, Matteo; Righi, Daniele; Ciuti, Gabriele; Liebgott, Herve; Ricci, Stefano
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0301562915000393-main.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 765.92 kB
Formato Adobe PDF
765.92 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/983801
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 63
  • ???jsp.display-item.citation.isi??? 61
social impact