The paper addresses the results of experimental and analytical investigations on composite systems able to reduce structural vulnerability of arches. Two composites, consisting of a PBO (propylbenzodioxole) fibre textile or a carbon fibre textile coupled with a cement-based matrix, are considered. Experimental results on bond capacity between composites and bricks and on the structural behaviour of unreinforced and extrados-reinforced 1:2 scale masonry arches, tested under vertical load, are presented. The global load slip law deduced from double-shear tests is employed to predict the load displacement path followed by an arch reinforced at the extrados through the two composites. The analytical model, which exploits stationarity of potential energy of acting forces, is validated through the experimental results on the reinforced reduced scale arch. Results show how the initial response is tackled by the model. The procedure could be refined and extended to other curved elements (e.g. pointed and ogee arches, vaults and domes) and loading conditions. A further improvement may come from the use of test results on convex surfaces, it being known that the bonding behaviour is improved with respect to that on plane surfaces.

Bond behavior of trm systems and reinforcement of masonry arches: Testing and modelling / Misseri G.; Stipo G.; Galassi S.; Rovero L.. - ELETTRONICO. - (2020), pp. 558-570. [10.1007/978-3-030-41057-5_46]

Bond behavior of trm systems and reinforcement of masonry arches: Testing and modelling

Misseri G.
;
Stipo G.;Galassi S.;Rovero L.
2020

Abstract

The paper addresses the results of experimental and analytical investigations on composite systems able to reduce structural vulnerability of arches. Two composites, consisting of a PBO (propylbenzodioxole) fibre textile or a carbon fibre textile coupled with a cement-based matrix, are considered. Experimental results on bond capacity between composites and bricks and on the structural behaviour of unreinforced and extrados-reinforced 1:2 scale masonry arches, tested under vertical load, are presented. The global load slip law deduced from double-shear tests is employed to predict the load displacement path followed by an arch reinforced at the extrados through the two composites. The analytical model, which exploits stationarity of potential energy of acting forces, is validated through the experimental results on the reinforced reduced scale arch. Results show how the initial response is tackled by the model. The procedure could be refined and extended to other curved elements (e.g. pointed and ogee arches, vaults and domes) and loading conditions. A further improvement may come from the use of test results on convex surfaces, it being known that the bonding behaviour is improved with respect to that on plane surfaces.
2020
978-3-030-41056-8
978-3-030-41057-5
Lecture Notes in Mechanical Engineering
558
570
Misseri G.; Stipo G.; Galassi S.; Rovero L.
File in questo prodotto:
File Dimensione Formato  
AIMETA_2019_Paper_268.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 945.49 kB
Formato Adobe PDF
945.49 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1196325
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact