The Luminex XMAP technology permits the simultaneous evaluation of numerous cytokines in several types of biological fluids (plasma, serum, liquor, follicular fluids, etc.) and in cell supernatants. Thus, multiplexing allows to achieve a time/cost economy and ensures that all the measurements are performed in the same conditions. Simultaneous measurement of cytokines with a multiplex bead-based assay has some similarities with ELISA, in particular the use of anti-cytokine antibodies, but shows an important difference, the use of magnetic fluorescent beads coupled to anti-cytokine monoclonal antibodies. The magnetic microspheres (dyed internally with two florescent dyes) coupled with anti-cytokine monoclonal antibodies are incubated with samples and standards; after washing, the samples/standards are incubated with biotinylated anti-cytokine monoclonal antibodies; and finally, after other washings, with streptavidin-phycoerythrin solution. Luminex instrument identifies the different cytokines present in each well and converts the mean fluorescence intensity (MFI) of each measured cytokine in pg/ml, thanks to the software and the standard curves. This technique is applicable in basic and clinical research.

Evaluation of Secreted Cytokines by Multiplex Bead-Based Assay (X MAP Technology, Luminex) / Lombardelli L., Logiodice F., Kullolli O., Piccinni MP.. - ELETTRONICO. - (2021), pp. 121-130. [10.1007/978-1-0716-1311-5_10]

Evaluation of Secreted Cytokines by Multiplex Bead-Based Assay (X MAP Technology, Luminex)

Lombardelli L.;Logiodice F.;Kullolli O.;Piccinni MP.
2021

Abstract

The Luminex XMAP technology permits the simultaneous evaluation of numerous cytokines in several types of biological fluids (plasma, serum, liquor, follicular fluids, etc.) and in cell supernatants. Thus, multiplexing allows to achieve a time/cost economy and ensures that all the measurements are performed in the same conditions. Simultaneous measurement of cytokines with a multiplex bead-based assay has some similarities with ELISA, in particular the use of anti-cytokine antibodies, but shows an important difference, the use of magnetic fluorescent beads coupled to anti-cytokine monoclonal antibodies. The magnetic microspheres (dyed internally with two florescent dyes) coupled with anti-cytokine monoclonal antibodies are incubated with samples and standards; after washing, the samples/standards are incubated with biotinylated anti-cytokine monoclonal antibodies; and finally, after other washings, with streptavidin-phycoerythrin solution. Luminex instrument identifies the different cytokines present in each well and converts the mean fluorescence intensity (MFI) of each measured cytokine in pg/ml, thanks to the software and the standard curves. This technique is applicable in basic and clinical research.
2021
978-1-0716-1311-5
T-Helper Cells
121
130
Goal 3: Good health and well-being for people
Lombardelli L., Logiodice F., Kullolli O., Piccinni MP.
File in questo prodotto:
File Dimensione Formato  
PICCINNI MPEvaluation of Secreted Cytokines by Multiplex Bead-Based Assay (X MAP Technology, Luminex).pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 446.89 kB
Formato Adobe PDF
446.89 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1237484
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact