Seven current methods of protein quantitation, Bradford (standard, micro, and 590/450 nm ratio), Lowry, bicinchoninic acid (BCA), UV spectrophotometry at 280 nm, and Quant-iT fluorescence-based determination, were compared with regard to their susceptibility to interferences due to the presence of suspended and not easily detectable clay particles. Bovine serum albumin (BSA) and Na-Wyoming montmorillonite were selected as model protein and reference clay, respectively. Protein-clay suspension mixtures were freshly prepared for each assay to simulate supernatants not completely centrifuged in batch sorption/kinetic experiments. Seven fixed increasing levels of clay (0.0, 0.00725, 0.0145, 0.029, 0.058, 0.145, 0.435 mg ml(-1)) were mixed with different levels of BSA in an appropriate range for each assay. To ascertain the interfering effect of different levels of clay, the theoretical concentrations of BSA were plotted against the estimated BSA concentrations of the samples, as obtained from the calibration curve of each method. A correct quantitation of the BSA concentration not influenced by clay would be described by a regression line with slope (b) not significantly different from 1 and an intercept (a) not significantly different from zero. At the lowest clay levels (0.00725 mg ml(-1)) a significant interference was evident for Bradford micro, Bradford 590/450, UV, and fluorescence. The three methods (Bradford standard, Lowry, and BCA) that seemed to show the better performances in the presence of clay after this first screening step also underwent an ANCOVA analysis, with the measured BSA concentrations as dependent variable and the clay concentrations as covariate. The Bradford standard and BCA methods were affected by a clay-dependent interference on BSA quantitation. The Lowry assay was the only method that gave correct estimates of BSA concentrations in the presence of any of the clay levels tested.
Interferences of suspended clay fraction in protein quantitation by several determination methods / Lozzi I; Pucci A; Pantani O; D'Acqui LP; Calamai L. - In: ANALYTICAL BIOCHEMISTRY. - ISSN 0003-2697. - ELETTRONICO. - 376:(2008), pp. 108-114. [10.1016/j.ab.2008.01.040]
Interferences of suspended clay fraction in protein quantitation by several determination methods
LOZZI, IRENE;PANTANI, OTTORINO-LUCA;CALAMAI, LUCA
2008
Abstract
Seven current methods of protein quantitation, Bradford (standard, micro, and 590/450 nm ratio), Lowry, bicinchoninic acid (BCA), UV spectrophotometry at 280 nm, and Quant-iT fluorescence-based determination, were compared with regard to their susceptibility to interferences due to the presence of suspended and not easily detectable clay particles. Bovine serum albumin (BSA) and Na-Wyoming montmorillonite were selected as model protein and reference clay, respectively. Protein-clay suspension mixtures were freshly prepared for each assay to simulate supernatants not completely centrifuged in batch sorption/kinetic experiments. Seven fixed increasing levels of clay (0.0, 0.00725, 0.0145, 0.029, 0.058, 0.145, 0.435 mg ml(-1)) were mixed with different levels of BSA in an appropriate range for each assay. To ascertain the interfering effect of different levels of clay, the theoretical concentrations of BSA were plotted against the estimated BSA concentrations of the samples, as obtained from the calibration curve of each method. A correct quantitation of the BSA concentration not influenced by clay would be described by a regression line with slope (b) not significantly different from 1 and an intercept (a) not significantly different from zero. At the lowest clay levels (0.00725 mg ml(-1)) a significant interference was evident for Bradford micro, Bradford 590/450, UV, and fluorescence. The three methods (Bradford standard, Lowry, and BCA) that seemed to show the better performances in the presence of clay after this first screening step also underwent an ANCOVA analysis, with the measured BSA concentrations as dependent variable and the clay concentrations as covariate. The Bradford standard and BCA methods were affected by a clay-dependent interference on BSA quantitation. The Lowry assay was the only method that gave correct estimates of BSA concentrations in the presence of any of the clay levels tested.File | Dimensione | Formato | |
---|---|---|---|
631.pdf
Accesso chiuso
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Tutti i diritti riservati
Dimensione
607.88 kB
Formato
Adobe PDF
|
607.88 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.