The Ultrasound Advanced Open Platform (ULA-OP) was recently developed with the specific goal of enabling the implementation of non standard working modalities, either in real-time or off-line, as made possible by the access to raw echo-data at each point of the receiver chain. Three case studies, demonstrating the fulfillment of initial specifications, are reported here. They consist in the implementation of: 1) a high frame rate (HFR) imaging approach producing images with uniform resolution; 2) an original real-time vector Doppler technique based on two US beams concurrently controlled by the on board DSP; 3) the simultaneous measurement of both the stimulus (wall shear stress increase) and the effect (diameter enlargement) in Flow Mediated Dilation (FMD) studies. In each of the aforementioned applications, the hardware & software resources of ULA-OP are differently exploited, showing that the system is a nice tool to implement non standard US modalities.
Implementation of non Standard Methods with the Utrasound Advanced Open Platform (ULA-OP) / E. Boni; L. Bassi; A. Dallai; F. Guidi; A. Ramalli; S. Ricci; P. Tortoli. - STAMPA. - (2011), pp. 466-469. (Intervento presentato al convegno 2011 International Ultrasonics Symposium tenutosi a Orlando, USA nel Ottobre 2011) [10.1109/ULTSYM.2011.0112].
Implementation of non Standard Methods with the Utrasound Advanced Open Platform (ULA-OP)
BONI, ENRICO;BASSI, LUCA;DALLAI, ALESSANDRO;GUIDI, FRANCESCO;RAMALLI, ALESSANDRO;RICCI, STEFANO;TORTOLI, PIERO
2011
Abstract
The Ultrasound Advanced Open Platform (ULA-OP) was recently developed with the specific goal of enabling the implementation of non standard working modalities, either in real-time or off-line, as made possible by the access to raw echo-data at each point of the receiver chain. Three case studies, demonstrating the fulfillment of initial specifications, are reported here. They consist in the implementation of: 1) a high frame rate (HFR) imaging approach producing images with uniform resolution; 2) an original real-time vector Doppler technique based on two US beams concurrently controlled by the on board DSP; 3) the simultaneous measurement of both the stimulus (wall shear stress increase) and the effect (diameter enlargement) in Flow Mediated Dilation (FMD) studies. In each of the aforementioned applications, the hardware & software resources of ULA-OP are differently exploited, showing that the system is a nice tool to implement non standard US modalities.File | Dimensione | Formato | |
---|---|---|---|
IUS2011-000106.pdf
Accesso chiuso
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Tutti i diritti riservati
Dimensione
1.2 MB
Formato
Adobe PDF
|
1.2 MB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.